Questions & Answers

Q: Can you give me an example of method how to adjust baseline ?

A: One example to share can be at a facility with an established baseline energy model within a well-defined measurement boundary. Into the reporting period an energy team review of energy performance observes an unexpected change in actual reporting period electrical consumption, which in this example negatively impacts the energy savings performance. Investigations by the energy team reveal the source of change is new fan equipment installed to meet new environmental requirements. The fan equipment is expected to operate in future reporting periods and to have minimal interactive effects with other facility equipment. Depending upon energy efficiency program M&V requirements or party contracts, quantifying the change in electrical consumption from the added environmental equipment can be accomplished by a number of well-established energy engineering methods based on energy impact and predictability of the new load. For example:


• For relatively small constant load changes, engineering calculations supported with equipment nameplate information.
• For relatively large constant load changes, engineering calculations supported with short-term data logging.
• For variable loads, long-term or permanent sub-metering.
• For variable loads when long-term sub-metering is not practical or feasible, developing an empirical model that correlates energy usage from the new equipment to key independent variables.

Going forward from the start of the documented installation date of the new equipment, the baseline energy model can then be adjusted by one of the above energy consumption quantification methods.

For treatment of baseline adjustments specific to industrial energy management, please reference BPA Energy Smart Industrial MT&R Reference Guide, Rev. 7, found in accompanying URL.
References
  1. https://www.bpa.gov/EE/Policy/IManual/Documents/MTR-Reference-Guide-Rev7.pdf

Q: I am an energy engineer at an ESCO located in Dubai, UAE.

My project is a high-rise residential tower with water-cooled chillers/cooling towers/primary constant-secondary variable chilled water pump configuration. The cooling network serves the whole building but the tenant spaces (apartments) are sub-metered for their cooling consumption using BTU meters from a third-party metering company. They are billed for their cooling consumption separately; however, the building's utility bills (electricity) cover the full building consumption.

For M&V purposes, I collect the utility bills monthly from the building manager and separately request the submetered tenant consumption.

My question is whether this method for savings calculation is legitimate. The equation I use is as follows:

Savings (kWh) = Baseline (kWh) ± Adjustments (kWh) - Verified Utility Actuals (kWh) + Submetered Tenant Consumption (kWh)

A1: If I am understanding your situation, your Savings equation is simply the Option C savings equation, so you are good there. But if I am reading this right, "Verified Utility Actuals" is the building's total electric use, right? The "Submetered Tenant Consumption" is a subset of the total building's electric use, or in other words, a subset of the "Verified Utility Actuals." So I don't think you want to add that submetered energy use into your savings calculation. This would be double counting that energy use. Those submetered data can provide you additional insight into the building's energy profile/energy use, but should appear in the savings calcs.

But maybe I am not clear on your situation.

A2: agree with Tracy. If your goal is to quantify whole building electrical savings, keep in mind your measurement boundary. The chilled water use is within the boundary for a whole building analyses, so you would not include the “Submetered Tenant Consumption” in your calculation.

Q: I have a question about how to use option C savings evaluation and how to overlay or use that information to inform EUL or apply a stipulated EUL to estimate lifetime savings for a collection implemented similar measures.
My use case is for a utility project that comprises 3 facilities and about 10 meters where will be "installing" RetroCommissioning. M&V is 2 years and EUL (median measure life) is stipulated by the regulator at 3 years. Do you have any methods or protocols suggestions for estimating the lifetime savings of the measures at the end of year two? Simply multiplying the sum of Y1&Y2 avoided energy use by 3/2 would assume that all measures will fail precisely at the end of year three, which would obviously under-estimate the lifetime savings. It seems like a survivorship problem (e.g. a 71 year old human is expected to live to an older age than an infant).

One other element is that after initial implementation of the RCx measures, we may stay engaged with the customer to monitor energy use and maintain the savings over the M&V period. How would this effect the approach to the prior problem statement.

A: This doesn't seem to be an M&V question, but rather a measure life methodology question for a group of measures, so its not strictly in the realm of M&V. I can suggest a few things to think about. First, how are RCx measure savings EUL determined? I don't mean by regulatory rule, but in persistence studies? RCx by nature is correcting building system operations, whether deficient, in need of repair, or improving control strategies. It seems the testing or analysis done to identify the measure can be repeated in years 1, 2, 3, 4 and so on. If your company stays engaged, this is a possibility. If not, maybe integrate these testing practices into the building's regular operations. At the outset, use a weighted average EUL for the combination of measures and determine the Option C savings associated with it (estimate normalized savings under typical conditions, as is the practice in cost-effectiveness calculations). With each successive year, see if the measures are still operating correctly. Determine some method for adjusting savings/EUL in the successive years as measures cease to save.

Q: I'm working on a project where we're looking at an Option C for electricity at a manufacturing site where the ECMs are all focussed around HVAC / lighting. There are so many changing product lines (different lines in baseline and reporting period!) that it's difficult find a consistent and reliable production variable, but, we do have sub-meter data for the production. Is it theoretically possible to use the production sub meter data as an independent variable for the whole site data? The thought is that the activity of the production lines has an impact on the HVAC / lighting loads (as well as other variables - degree days etc.) and so we're just using energy consumption of the production lines as a proxy for production activity. However, it doesn't feel comfortable to us as the sub-meter data is not independent of the dependent variable (i.e. the whole site data)!! Does anyone have any views / experience with this? Is this a regression analysis faux pas? Very grateful for any thoughts.

A:  I agree that the method you describe is not quite typical. It is more common to use a production metric as the independent variable. That said, there are definitely times when no clean production variable is available. It may not be recorded or product lines may change so quickly that there is no common element. In those cases, I think you have hit upon a clever and acceptable approach. It works in this case because you are not attempting to estimate savings on the production lines.

You say that “the sub-meter data is not independent of the dependent variable (i.e. the whole site data)”. That would be true if the dependent variable was the whole facility use. However, in your case I think you can isolate on the HVAC and Lighting loads. I recommend subtracting the submetered use from the whole facility use. That will give you the Lighting and HVAC use, plus some noise. Try regressing that net load against your production variable (kWh) and whatever other variables you are considering.

One uncertainty to consider is how much (if any) non-production load is actually served by the "production" submeter? If any of your lighting or HVAC is on that meter, you will miss those savings.

Q: I am currently working on the reduction of electrical or thermal power in building rehabilitation. I would have liked to know if you had any documentation on this subject. In particular, either feedback on similar actions or methods of measurement and verification.
Regards,

A: Assuming that "building rehabilitation" means significant changes and modernization or improvements to the building and/or systems. (In the United States, this is referred to as "deep retrofits" which is not any clearer, in my opinion.) If that is the correct meaning, then a likely approach for M&V would be IPVMP Option C. Software that can help with the analysis for IPMVP Option C is ECAM, which is available in French as well as English. Contact Paul Calberg-Ellen at Biomasse Normandie or Sidonie Michel at Observatoire Régional Energie Climat Air Normandie to find out how to obtain the French version of ECAM.

Q - I am making a multiple regression for C EVO model. Constant values (m1,m2 and m3) according to the equation y(consumption)= m1(days)+m2(activity hours)+ m3(HDD)+b results with negative values; What should I do?

1.- If constant b<0 ; is it possible the building had negative consumption if no other variables affect?
2.- If constant m1<0
3.- If constant m2<0
4.- If constant m3<0

What is the procedure in these cases?

A - Unless there is energy production (e.g. solar panels) within the measurement boundary, the estimated consumption should never be less than zero.

The coefficients should always make physical sense. Without know the full meeting of your equation, I would expect m1 and m2 to be positive. For example, it wouldn't usually make sense that energy use could go down as the number of days increased.

m3 should usually be positive. Possible issues include an incorrect base temperature for HDD or allowing negative values for HDD.

Last, but not of least importance, you should not be extrapolating outside the range of independent variables in your data. If you extrapolate, in some cases you can get negative estimates of energy use. For high frequency data (e.g. daily or hourly) we are having discussions about if or when minor extrapolation could be allowed, but right now IPMVP does not allow extrapolation. (It is certainly possible that a reporting period could have a month with slightly more (or fewer) HDD than was present in any month in the baseline even with a full year baseline, and so even at present it might make sense to have VERY MINOR extrapolation, but it should be avoided.